红外测温自动化集成应用,坯料、模具在线测温方案|Infrared Pyrometers in Forging Automation: Billets and Dies
摘要:红外测温是锻造自动化获取温度数据的核心传感器,本文讲坯料、模具红外测温选型、吹扫防护、信号接入 PLC 常见问题。
Abstract: Infrared pyrometers are the core temperature sensors of forging automation. This article covers selection for billets and dies, purge protection, and PLC signal integration.
正文: 锻造现场高温、粉尘、水汽多,红外测温用来非接触读取坯料锻造温度、模具温度,把温度信号给到电控系统实现闭环控制。
Main text: Forge shops are hot, dusty and wet. Infrared pyrometers read billet and die temperatures without contact and feed the control system for closed-loop operation.
两个应用场景
Two use cases
- 坯料出口测温:感应加热炉出口检测坯料实际温度,反馈调节加热功率;温度不合格坯料自动分流剔除,不进入锻打。
Billet exit temperature: measure real billet temperature at the furnace exit, feedback to heating power; out-of-tolerance billets are diverted before forging. - 模具测温:监控模具工作温度,联动自动润滑、模具预热系统。
Die temperature: monitor die temperature and interlock with automatic lubrication and preheating.
自动化集成要点
Integration essentials
- 镜头吹扫保护:必须配压缩空气吹扫,隔绝粉尘、水汽、石墨喷雾,否则镜头被遮挡读数完全失真。
Lens purge: compressed-air purging is mandatory – dust, moisture and graphite spray will blind the lens completely. - 选型:根据被测温度区间选测温仪;高温锻件选用短波红外,抗环境干扰更好。
Selection: match the pyrometer to the temperature range; short-wavelength models resist interference better on hot forgings. - 信号输出:4‑20mA 或者通讯协议接入 PLC,不要只靠显示屏人工看。
Signal: use 4-20 mA or a fieldbus into the PLC – not just a local display someone glances at. - 定期校准:避免漂移。
Calibration: calibrate regularly to prevent drift.
常见踩坑
Classic mistake
很多工厂买回来红外测温仪,不装吹扫,短时间就被粉尘盖住,设备形同虚设。
Many plants buy pyrometers without purges; dust coats the lens within weeks and the instrument does nothing.
小结
Summary
红外测温只是传感器,真正价值是接入自动化控制系统,实现闭环控制;吹扫防护是现场稳定工作的必要条件。
A pyrometer is just a sensor – its value comes from closing the loop in the control system, and purge protection is what keeps it alive on the floor.